System | 5G NR FDD/TDD |
Frequency Range * | 3700~4000 MHz (TDD n77) 3300~3600 MHz (TDD n78) 2500~2700 MHz (TDD n41) 1920~1980 / 2110~2170 (FDD UL/DL n1) 1710~1785 / 1805~1880 (FDD UL/DL n3) |
Max. Sub-block Bandwidth | 100 MHz |
Number of Sub-block | Up to 4 Sub-block |
Max. Output Power UL/DL | 17/17 dBm ± 2dB |
Max. Gain UL/DL | 40~60 dB ± 2 dB, 1 dB/step, Manual or Auto Gain Control Support |
Gain Flatness | <= 3 dBpp within 100 MHz |
Group Delay | <= 3.0 μs |
UL/DL EVM | <= 3.5% (at Max. Output Power) |
UL Noise Figure | <= 6 dB (at Max. Gain) |
VSWR | <= 1.8 |
Max. Input Power Without Damage | >= 0 dBm (UL&DL) |
Out-of-band Gain Rejection | Compliant to 3GPP TS 38.106 |
Adjacent Channel Leakage Ratio | Compliant to 3GPP TS 38.106 |
Frequency Stability | Compliant to 3GPP TS 38.106 |
Spurious Emission | Compliant to 3GPP TS 38.106 |
Unwanted Emission (Emission Mask) | Compliant to 3GPP TS 38.106 |
TDD Synchronization | Automatic Frame Start Time Acquisition Rx Sensitivity: -88 dBm for 100 MHz and 30 kHz SCS User-set TDD Slot Format for RF SW Control |
Built-in Antenna ** | Antenna Gain >= 5dBi for Frequency Band < 1700MHzAntenna Gain >= 5.5dBi for Frequency Band > 1700MHz Automatically Switch Off When Using DC-Short External Antenna |
Antenna Port | SISO (or 2x2 MIMO Optional) SMA Female RF Connector |
Impedance | 50Ω |
Power Adapter | Input: AC 100~240V, 50/60Hz Output: DC 12V/3A (SISO), 12V/5A (2x2 MIMO) |
Power Consumption *** | < 22W for SISO, < 40W for 2x2 MIMO |
Dimensions *** | 200 x 156 x 50 mm (excluding RF connector) |
Weight *** | <= 2.5kg |
Operating Temperature | 0°C ~ +55°C |
MTBF *** | 50,000 hrs |
Automatic Shutdown Function | RSSI Overpower Shutdown (Max. -20 dBm ± 2 dB, OMT Programmable) RSSI Underpower Shutdown (Min. -86 dBm ± 2 dB, OMT Programmable) |
LED Indicators | RSSI: Green LED x 3 to Indicate Receive Power Level ALM: Red LED x 1 to Indicate the Unit Is Alarming STATE: Green LED x 1 to Indicate Operating Status (Blinking: Out-of-sync, Solid: In-Sync) |
Local Control | OMT: PC Tool or Android APP Connection: USB Type-C OTG Cable or BT (Optional) |
Remote Control | OMC: Web Server Connection: MQTT/TCP/IP or SNMP/UDP/IP RCU with IoT Modem (Optional) |